Abstract/Details

A clinical protocol for attenuation and scatter correction of thallium-201 and Sestamibi myocardial perfusion SPECT images


1999 1999

Other formats: Order a copy

Abstract (summary)

Photon attenuation and scatter in myocardial perfusion SPECT are major sources of diagnostic uncertainty because they affect both the qualitative and quantitive characteristics of patient images. Recent studies have demonstrated improved performance in the diagnostic accuracy of Sestamibi myocardial perfusion SPECT images when using attenuation corrected images [1]. One technique for correcting for attenuation uses a short (65 cm) focal length fan beam collimator and a line Methods for correcting images for scatter using adjacent energy windows have also been proposed. Though methods for correcting for these problems exist, implementation in a clinical setting has been difficult.

We have developed a clinical protocol for performing attenuation and scatter correction. The system uses a fan-beam collimator and a line source of activity on a PRISM 3000, triple head camera system for acquiring transmission data. For acquiring emission data, parallel hole collimators are placed on the two other camera heads to determine: (1) the photo-peak image, (2) the scatter contribution to the photo-peak image, and (3) a large scatter window for estimating the body outline. The body outline is used as a spatially varying gamma prior for correcting the transmission image for the effects of object truncation. Presented herein is also a method of automatically selecting a spatially varying Gibbs prior to control the noise in the iterative reconstruction. The method of Ordered Subsets-Expectation Maximization is also used to accelerate the reconstruction of the images [2].

We observed in phantom studies that correcting images for attenuation and scatter will reduce the effects of these artifacts but may emphasize other effects, i.e. detector response, patient motion, etc. Improvements in uniformity of myocardial images were observed for Sestamibi phantom studies using a breast attenuator which partially obscured the heart. However, less significant improvements were observed using 201Tl where the heart was completely obscured by the breast attenuator.

This protocol demonstrated that clinical implementation of attenuation and scatter correction is possible without significant adjustment of clinical routine. However, because of the residual artifacts present in the corrected images, it is necessary to obtain simultaneously data for reconstructing images using traditional FBP protocols. in conjunction with correction protocols.

Indexing (details)


Subject
Biophysics;
Radiology
Classification
0760: Biophysics
0574: Radiology
Identifier / keyword
Health and environmental sciences, Biological sciences, Attenuation, Clinical protocol, SPECT, Scatter correction, Sestamibi myocardial perfusion, Thallium-201
Title
A clinical protocol for attenuation and scatter correction of thallium-201 and Sestamibi myocardial perfusion SPECT images
Author
Case, James Arthur
Number of pages
173
Publication year
1999
Degree date
1999
School code
0118
Source
DAI-B 61/01, Dissertation Abstracts International
Place of publication
Ann Arbor
Country of publication
United States
ISBN
9780599622623, 0599622628
Advisor
King, Michael A.; Rabin, Monroe S. Z.
University/institution
University of Massachusetts Amherst
University location
United States -- Massachusetts
Degree
Ph.D.
Source type
Dissertations & Theses
Language
English
Document type
Dissertation/Thesis
Dissertation/thesis number
9958859
ProQuest document ID
304516631
Copyright
Database copyright ProQuest LLC; ProQuest does not claim copyright in the individual underlying works.
Document URL
http://search.proquest.com/docview/304516631
Access the complete full text

You can get the full text of this document if it is part of your institution's ProQuest subscription.

Try one of the following:

  • Connect to ProQuest through your library network and search for the document from there.
  • Request the document from your library.
  • Go to the ProQuest login page and enter a ProQuest or My Research username / password.